Stator Tester ST 510

- Non-destructive testing of the magnetic properties of stators
- Quality control of unwound stators in seconds, irrespective of size
- Fully automatic measuring station, safety light barrier
- Time-consuming manual preparation of samples is no longer necessary
- Integration into production line, 100 % testing possible
- Interactive recording of measuring data which can be saved in external programmes
- Identification of all relevant measuring values
Operating principle
The testing station consists of a testing cage made from aluminium profiles. The front section is fitted with a safety light shield. This guarantees very quick operating processes.
The stator package is fixed via a horizontal drill hole into a small prism. When the area of the safety light barrier is clear the testing process can be started by using the start button. Then a u-shaped bracket with 23 windings moves into the stator and makes contact with the opposite side. The measurement is started with a start signal.
If the measuring result is positive (the stator corresponds to the norm) the u-shaped bracket recedes and the measuring sample can be removed. If the result is negative (the stator does not meet the norm) the u-shaped bracket remains closed - a lamp lights up - and can only be released by activating a switch manually.
Measuring categories
- Specific hysteresis loss [W/kg]
- Maximum polarisation [T]
- Effective polarisation [T]
- Maximum field strength [A/m]
- Effective field strength [A/m]
- Remanence [T]
- Coercive field strength [A/m
- Permeability
- Spezific apparent output [VA/kg]
- AC hysteresis curve
The measured values are displayed on a monitor and can be printed out. Transmission to the PC is possible via an ARCNET interface. MPG Expert 2.x software controls the equipment and displays the results (Windows 98/ME/NT/2000/XP).
| Technical data: | Stator Tester ST 510 |
| Selectable measuring frequencies: | 12 Hz - 100 Hz (in 0.1 Hz steps) |
| Selectable field strength: | 10 A/m - 10.000 A/m |
| Induction: | 100 mT - 2 T |
| Repeatiability: | better 1 % ( ± 1digit) |
| Comparability of measuring results: | according to IEC 60404-3 |
| Maximum current: | ± 105 A |
| Maximum voltage: | ± 32 V |
| Coil connectors: | 3 |
| Operating mode: | PC / software |
| Power supply: | 105 - 125 V AC or 220 V AC, 50/60 Hz, 0.6 kVA |